Double filter in a drawer system – filter change without dismantling. Illuminated small spray booth, approx. 1250 × 1500 × 2150 mm, 400 V, on castors or as floor-standing model. For trials, sample panels and small parts where material and colour change frequently. Extraction volume, air speed, exhaust connection and Ex suitability: on request. KUNDE: extraction volume m³/h or air speed m/s at the opening — without this figure no viable entry (concept question 12)
Key figures
- Dimensions (L × W × H)
- approx. 1250 × 1500 × 2150 mm
- Voltage
- 400 V
- Filter
- Double-drawer filters
- Installation
- Castors or stand
Solves your problem if …
- … you paint samples, trial panels or small parts and change material or colour frequently.
- … you want to change the filter quickly: coarse and fine filter sit in two drawers.
- … your workpiece fits into a booth of approx. 1250 × 1500 × 2150 mm and 400 V is available.
- … you want to move the booth (castors) or install it permanently (floor-standing model).
Not the right choice if …
- To be clarified on request: solvent-based paints (flash point < 21 °C) – Ex suitability of fan and light on request. KUNDE: Ex protection motor/light
- To be clarified on request: exhaust to the outside – connection and duct routing on request; recirculation is not permitted for manual painting under DGUV 209-046. KUNDE: exhaust spigot, diameter, position
- To be clarified on request: required capture velocity at the opening (DGUV 209-046: spray stand ≥ 0.5 m/s) – extraction capacity on request. KUNDE: m³/h, m/s
- … you paint large parts or series – the booth is designed for trials and samples.

How the small spray booth works
VISECO describes it in one sentence: "Small spray booth for trials and sample production with double filter in a special drawer system for quick filter changes."
The booth is made of sheet steel with an open front, light in the ceiling behind glass, cardboard filter as rear wall, floor filter of cardboard with fleece in a pull-out drawer, two drawer fronts with handles, castors. KUNDE: confirm functional description — material, filter guidance, change procedure
Main image: ASSET FEHLT: photo ≥ 1500 px with workpiece or person — today a studio photo without application context
ASSET FEHLT: photo or short sequence of the filter change — the only selling point is not shown · ASSET FEHLT: dimension drawing of outer/inner/opening dimensions, table height, exhaust spigot
Applications
Trials and sample production
laboratory, application engineering, sample building.
KUNDE: confirm industries and use cases — derived from 02-produkte: application engineering at paint/coating manufacturers, sample building in the furniture/wood industry, small parts at automotive suppliers and injection molders, test and training stations. None of this is documented. KUNDE: Is the booth used in Aichach as a demonstration/test station for Airtherm, WarmUp, Duoline and pressure tank? If so, mention it here and activate the SAMPLE path
Technical data small spray booth
| Dimensions (L × W × H) | approx. 1250 × 1500 × 2150 mm |
|---|---|
| Voltage | 400 V |
| Filter system | double filter drawer system for coarse and fine filter |
| Lighting | illuminated KUNDE: lux, Ex zone of the light |
| Installation | on castors or as floor-standing model |
| Extraction volume | KUNDE: m³/h |
| Air speed at the opening | KUNDE: m/s |
| Fan / motor | KUNDE: kW, Ex protection, noise level |
| Exhaust connection | KUNDE: diameter, position |
| Filters (type, area) | KUNDE: coarse/fine filter specifically, m²; do the VISECO Andreae rolls fit? |
| Inner/opening dimensions, table height | KUNDE |
| Weight, material | KUNDE |
| Electrical connection | KUNDE: power, plug-ready CEE? |
| As of | 17 Sept 2026; no data sheet available. |
Versions and options
| Version / option | Difference |
|---|---|
| On castors | mobile |
| Floor-standing model | permanently installed |
| Article numbers, surcharges, options (turntable, special dimensions, Ex light, exhaust duct set) | on request. Extraction box as bench-top unit: KUNDE: own product? |
In the system with …
KUNDE: demonstration booth for hot wax and Airtherm systems — substantiate or delete
Paint booth filters
Andreae paint booth filters: The booth uses cardboard filters as rear wall and floor filters. → Andreae paint booth filters KUNDE: confirm filter type and size so that the re-order link is correct
Certificates and standards
Product-specific
VISECO states neither a CE declaration nor applied standards. KUNDE: EN 16985, DIN EN 14986 (fan), Ex information
ISO 9001:2015 (company)
DIN EN ISO 9001:2015, TÜV SÜD, reg. no. 12 100 34086 TMS, valid until 8 July 2029.
Regulatory context for the operator (not a certificate)
DGUV Information 209-046: horizontal air flow at least 0.5 m/s, no recirculation for manual painting; fan spark-proof, lights in zone 2 at least IP 54.
Downloads
- None.
- Data sheet: omitted –
Inquiry small spray booth
You will receive a technical reply or a quote from VISECO in Aichach. KUNDE: response time and contact person
So that we can clarify version and suitability, please tell us:
- Version (castors / floor-standing):
- Workpiece size (mm) / sample format:
- Paints (water-based / solvent-based; flash point):
- Exhaust to the outside possible (yes / no):
- 400 V supply available (yes / no):
- Location (town, country):
- Company, contact person, phone:
KUNDE: confirm which details VISECO really needs
Helpful as attachment: sketch of the installation site with exhaust route, safety data sheet of the paints.
How to reach us
E-mail in plain text: kontakt@viseco.de.
Related products

Hot wax spray gun
Hot wax spray gun
Liquefies wax, oil or release agent in the heated 0.4 l cup and sprays it directly – no pre-melting, no solvents, the material can stay in the cup.